
Composite Shingle Installation by ARCM Roofing
Polymer, fiberglass, and recycled materials engineered into shingle systems that outlast, out-resist, and out-warranty traditional asphalt.
5 Highlights on Composite Shingles
Shingle Format. Engineered Substance.
The shingle-format tier of synthetic roofing — spanning full-polymer systems to polymer-modified impact lines, all Class 4 rated, all chosen for how they handle Colorado hail.
UL 2218 Class 4 Impact Rating
Rated to withstand hail up to two inches in diameter — the escape hatch from the Front Range claim cycle, often insurer-discounted.
UV Inhibitors All the Way Through
Asphalt protects itself with surface granules that wash away. Composite shingles carry UV inhibitors throughout the material — nothing to shed, nothing to erode.
Slate and Shake Profiles, Half the Weight
Authentic architectural profiles at roughly half natural slate's load — most homes need zero structural reinforcement.
Class A Fire Ratings
The highest fire classification on every line we install — a clean answer for WUI addresses.
30-to-50-Year Warranties
From polymer-modified impact lines to full-polymer systems, warranties outlast traditional asphalt by decades.
No granules to shed. No mat to dry out. Nothing to rot.
Why Choose Us
Trained on the Full Impact Spectrum
Our crews are manufacturer-trained on DaVinci Roofscapes and CertainTeed composite lines — nailing patterns and exposure specs differ from standard asphalt, and following them is what keeps your extended warranty tiers intact.
Every deck gets waterproofed before a single shingle goes down: self-adhering ice and water shield at eaves and valleys, synthetic underlayment across the field, corrosion-resistant metal at every valley, chimney, and sidewall. That attention separates a roof that lasts 50 years from one that leaks in five.
You get a written scope with fixed pricing, a dedicated project manager who answers calls, magnetic sweeps before we leave, and our 10-year workmanship warranty alongside 30-to-50-year manufacturer coverage.

Impact-rated and cool-roof colorways included in every sample walkthrough — see the product against your actual siding and trim.
When It Makes Sense
Signs Composite Shingles Are the Right Upgrade
Curling, Cupping, or Clawing Asphalt
When shingle edges lift or corners turn upward, the mat has dried out and lost its seal. Wind-driven rain penetrates beneath the tabs. Composite replacement stops the patch-repair cycle.
Granules Filling Your Gutters
Granules are asphalt's only UV defense, and heavy deposits in downspouts mean the surface is eroding. Composite shingles carry inhibitors through the full material thickness — there's no sacrificial layer to lose.
Repeated Hail and Storm Claims
Multiple insurance claims for hail bruising or wind-torn shingles signal a roof mismatched to its climate. A Class 4 composite roof breaks the pattern, and some insurers discount premiums for it.
Cracked Slate or Splitting Shakes
Natural slate fractures underfoot and cedar splits, rots, and grows moss. Composite shingles keep the architectural profile with a fraction of the weight and none of the biological decay.
A Roof Past 20 Years Old
Three-tab asphalt declines sharply after two decades — algae streaks, exposed fasteners, ceiling stains. A composite installation resets the clock for 50 years instead of 20.
Ready to leave the 20-year cycle? Get the fixed written quote.
How We Work
Our Composite Shingle Process
01
Inspection and Measurement
Our estimator inspects your existing roof, measures every plane and pitch, and documents deck condition, ventilation, and flashing points.
02
Material Selection
Style, color, and warranty tier chosen with physical samples against your siding and trim — including impact-rated and cool-roof colorways.
03
Tear-Off and Deck Preparation
Old roofing stripped to the deck, rotted sheathing replaced, debris hauled the same day. No overlays — they void manufacturer warranties.
04
Underlayment and Waterproofing
Self-adhering ice and water membrane at eaves and valleys, synthetic underlayment across the full deck.
05
Flashing and Edge Metal
Drip edge installed; chimneys, skylights, and wall intersections flashed; every pipe boot and vent penetration sealed.
06
Shingle Installation
Manufacturer nailing patterns, exposure specs, and staggered coursing for a uniform finish from eave to ridge.
07
Ridge, Ventilation, and Cleanup
Ridges capped, balanced intake and exhaust verified, magnetic sweeps run, final walkthrough completed with you.
Most residential projects finish in two to four days.
Brands We Use
From Full Polymer to Polymer-Modified
DaVinci Roofscapes
Synthetic slate and shake tiles
F-Wave
REVIA synthetic shingles with Class 4 ratings
Brava Roof Tile
Composite Spanish tile and cedar shake
EcoStar
Recycled rubber and plastic slate tiles
Enviroshake
Engineered composite shake roofing
Malarkey
Polymer-modified impact shingles
Atlas
StormMaster impact-rated shingles
CertainTeed
Presidential composite lines
GAF
Underlayment and accessory systems
Owens Corning
Deck protection components
OSHA fall protection with harnesses, roof anchors, and guarded ladder access on every project — safety protects our team and your property, and we don't cut corners on either.
FAQs
FAQs About Composite Shingles
›What is composite shingle installation?
Composite shingle installation is the process of fitting engineered shingles made from polymers, fiberglass, and recycled materials onto a prepared roof deck. The shingles replicate slate, cedar shake, or architectural asphalt profiles while delivering stronger impact and fire resistance.
›How long does composite shingle installation take?
Most residential projects take two to four days. Roof size, pitch, tear-off complexity, and weather affect the schedule. Our project manager gives you a firm timeline before work starts.
›When should I schedule composite shingle installation?
Spring through fall offers the widest scheduling windows, though our crews install composite shingles year-round when temperatures allow proper sealing. Book early if you want your roof finished before storm season.
›Why do composite shingles cost more than asphalt?
The material lasts two to three times longer, resists hail that destroys asphalt, and carries warranties up to 50 years. Many homeowners recover part of the cost through insurance premium discounts and avoided repairs.
›Can composite shingles go over my existing roof?
No. We tear off old roofing down to the deck so we can inspect the sheathing, replace damaged sections, and waterproof the surface correctly. Overlays void most manufacturer warranties.
›Does composite shingle installation come with a warranty?
Yes. Manufacturer warranties run 30 to 50 years depending on the product line, and ARCM Roofing backs the labor with our 10-year workmanship warranty. Certified installation qualifies you for extended coverage tiers.
Related Services
Fifty-Year Shingles for a Twenty-Year Climate.
UL 2218 Class 4 · Class A fire · Through-material UV defense
